hydraulic flow regulator / for water / for centralized lubrication systems
Fact 2000
Vnation JSC

-
Technology:
hydraulic
-
Fluid:
for water
-
Other characteristics:
for centralized lubrication systems
Flow Rate Meter
Specifications:
- Power supply Automatic range: 85?260VAC - 50/60 Hz
- Power absorption: 30 W
- Input signals Flow meters: 24 V DC
- Output signals:
? Servo Motors control for motorized Flowmaster 12 VDC
? Remote alarm 250 V 1A (switch)
- Max Distance between FACT-2000 and FACT-Expander: 20 m (55 ft)
- Operating temperature: - 5?C ? + 55?C (-41?F ? +131?F)
- Storage temperature: -20?C ? +65?C (-68?F ? +149?F)
- Operating humidity: 90% max
In medium/large lubrication systems it is often necessary to monitor separately and control the flow of each lubrication points. FACT-2000 was designed to monitor and control (via motorized Flowmasters) the lubricant flow. This controller is particularly suitable for medium/large lubrication systems.
System modularity allows system expansion without replacing the controller. Each FACT-2000 can monitor and control up to 16 Flowmasters, both manual and/or motorized.
The following accessories extend FACT-2000 monitoring and control power:
- Fact Expander: expansion to be connected to central unit. It can control further 16 Flowmasters. Controller can be connected to other 3 expansion units, reaching a whole capacity of control of 64 Flowmasters. Fact Expanders can be connected to FACT-2000 in cascade and are automatically configured.
- FACT software: a software to control remotely (by serial line RS-485) up to 32 controllers: so a PC, remotely holding 32 controllers (each controller connected to 3 expansions in cascade), can control up to 2048 flowmasters.